Support Industrielle sensorer
Support Explosion Protection

Guided Level Radar LTC51

LTC51
  • Premium device for level measurement in liquids
  • Measuring range up to 45 m (148 foot)
  • Process connection from 3/4 inch thread or flange
  • Temperature range up to 200 °C (392 °F)
  • Pressure range up to 40 bar (600 psi)
  • Up to SIL 3 acc. to IEC/EN 61508

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Uddrag af datablad: Tekniske data for   LTC51

General specifications
Measuring methodThe device is a measuring system that functions according to the time-of-flight method. The distance from the reference point (process connection of the measuring device) to the product surface is measured.
Construction typedevice with rod probe
device with coax probe
device with rope probe
SeriesLTC51
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Supply
Rated voltage11.5 ... 35 V DC, 2-wire
10.4 ... 48 V DC, 4-wire
90 ... 253 V AC, 50/60 Hz
Input
Measured variabledistance between reference point and product surface
Measurement rangerod probe: 4 m/10 m (13 ft/33 ft) (for divisible/indivisible rod probes)
coax probe: 6 m (20 ft)
rope probe: 45 m (148 ft)
Output
Output signal4 ... 20 mA
2 x 4 ... 20 mA
Communication4 ... 20 mA HART (standard)
PROFIBUS PA (option)
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2006 , EN 61326-2-3:2006
Low voltage
Directive 2014/35/EUEN 61010-1:2010
Conformity
Degree of protectionIEC 60529:2001
Measurement accuracy
Accuracydigital:
- measuring range up to 15 m (49 feet): ±2 mm (0.08 inch)
- measuring range > 15 m (49 feet): ±10 mm (0.39 inch)
analog: 0.02 %
sum of non-linearity, non-repeatability and hysteresis included in the maximum measured error
Operating conditions
Process conditions
Process temperature-40 ... 200 °C (-40 ... 392 °F)
Process pressure (static pressure)-1 ... 40 bar (-14.5 ... 580.2 psi)
Dielectric constantrod probe: DC ≥ 1.6
coax probe: DC ≥ 1.4
rope probe: DC ≥ 1.6
Ambient conditions
Ambient temperature-40 ... 80 °C (-40 ... 176 °F)
Mechanical specifications
Degree of protectionIP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep)
IP66, NEMA 4X
Connectiongland M20
thread M20, G1/2, NPT1/2
device plug M12, 7/8 in
Materialmaterials in contact with process :
rod probe, coax probe: 1.4404/316L
rope probe: 1.4401/316
process connections: 1.4404/316L, 2.4602/Alloy C22
process membran, seal: Viton, EPDM, Kalrez, gas-tight feed through as option
Process connectionthreads: from 3/4 in
flanges: DIN EN from DN40, ANSI from 1-1/2 in, JIS from DN40
Data for application in connection with hazardous areas
EU-type examination certificatesee instruction manuals (SI)
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-1:2007 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 60079-31:2009
International approvals
IECEx approvalsee instruction manuals (SI)
Certificates and approvals
Overspill protectionsee approval (ZE)
Telecommunicationsradio license FCC
General information
Supplementary documentationtechnical information (TI)
manuals, brief instructions (BA, KA)
instruction manuals (SI)
approval (ZE)
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Accessories
Designationsee technical information (TI)

Classifications

SystemClasscode
ECLASS 13.027200513
ECLASS 12.027200513
ECLASS 11.027200513
ECLASS 10.0.127200513
ECLASS 9.027200513
ECLASS 8.027200513
ECLASS 5.127200513
ETIM 9.0EC002995
ETIM 8.0EC002995
ETIM 7.0EC002995
ETIM 6.0EC002995
ETIM 5.0EC001447
UNSPSC 12.141111950

Details: LTC51

Datasheet: LTC51

DatasheetFil typeFil størrelse
Datasheet LTC51PDF1938 KB
Datenblatt LTC51PDF1933 KB

Documents: LTC51

ManualsFil typeFil størrelse
BA01006O, Manual LTC51 PROFIBUS PAPDF3675 KB
BA1001O, Manual LTC51 HARTPDF3925 KB
BA01006O, Handbuch LTC51 PROFIBUS PAPDF3689 KB
BA1001O, Handbuch LTC51 HARTPDF3945 KB
Instruction manuals
SI00496O, Instruction manual LTC50, LTC51, LTC57PDF1164 KB
SI00496O, Instruction manual LTC50, LTC51, LTC57PDF1162 KB
SI00496O, Betriebsanleitung LTC50, LTC51, LTC57PDF1167 KB
ZE01001, Zulassung WHG Z-65.16-542, LTC50, LTC51PDF1444 KB
Short instructions, safety information
KA1077O, brief instructions LTC51 HARTPDF1958 KB
KA1079O, brief instructions LTC51 PROFIBUS PAPDF1617 KB
KA1077O, Kurzanleitung LTC51 HARTPDF1967 KB
KA1079O, Kurzanleitung LTC51 PROFIBUS PAPDF1615 KB
Technical information
Contamination declaration / KontaminationserklärungPDF137 KB
TI01001O, Technical Information LTC51PDF5101 KB
TI01001O, Technische Information LTC51PDF5114 KB
Application reports
Application Report - Reliable Level Measurement with Explosion ProtectionPDF214 KB
Applikationsbericht - Zuverlässige Füllstandsmessung mit ExplosionsschutzPDF215 KB
Documents
SD00326O, Functional Safety Manual LTC5XPDF3235 KB
SI00497O, Instruction manual LTC51PDF1062 KB
SI00498O, Instruction manual LTC50, LTC51, LTC57PDF1249 KB
SI00499O, Instruction manual LTC50, LTC51PDF1140 KB
SI00500O, Instruction maunal LTC50, LTC51PDF1475 KB
SI00502O, Instruction manual LTC50, LTC51, LTC57PDF1281 KB
SI00503O, Instruction manual LTC50, LTC51, LTC57PDF1230 KB
SI00516O, Instruction manual LTC50, LTC51, LTC57PDF1299 KB
SI00517O, Instruction manual LTC51PDF1187 KB
SI00518O, Instruction manual LTC50, LTC51, LTC57PDF1550 KB
SI00519O, Instruction manual LTC50, LTC51PDF1152 KB
SI00520O, Instruction manual LTC50, LTC51PDF1527 KB
SI00522O, Instruction manual LTC50, LTC51, LTC57PDF1180 KB
SI00523O, Instruction manual LTC50, LTC51, LTC57PDF1168 KB
SI00529O, Instruction manual LTC50, LTC51, LTC57PDF881 KB
SI00530O, Instruction manual LTC50, LTC51, LTC57PDF1094 KB
SI00531O, Instruction manual LTC50, LTC51, LTC57PDF1093 KB
SI00532O, Instruction manual LTC50, LTC51, LTC57PDF875 KB
SI00570O, Instruction manual LTC50, LTC51, LTC57PDF623 KB
SI00571O, Instruction manual LTC50, LTC51, LTC57PDF842 KB
SI00572O,Instruction manual LTC50, LTC51, LTC57PDF626 KB
SI00573O,Instruction manual LTC50, LTC51, LTC57PDF841 KB
SI01125O, Instruction manual LTC50, LTC51, LTC57PDF1261 KB
SI01126O, Instruction manual LTC50, LTC51, LTC57PDF1258 KB
SI01127O, Instruction manual LTC51PDF1144 KB
SI01128O, Instruction manual LTC51PDF1152 KB
SI01130O, Instruction manual LTC50, LTC51, LTC57PDF1386 KB
SI01131O, Instruction manual LTC50, LTC51, LTC57PDF1382 KB
SI01132O, Instruction manual LTC50, LTC51, LTC57PDF1253 KB
SI01133O, Instruction manual LTC50, LTC51PDF1383 KB
SI01134O, Instruction manual LTC50, LTC51PDF1543 KB
SI01135O, Instruction manual LTC50, LTC51PDF1372 KB
SI01136O, Instruction manual LTC50, LTC51, LTC57PDF1305 KB
SI00497O, Instruction manual LTC51PDF1059 KB
SI00498O, Instruction manual LTC50, LTC51, LTC57PDF1246 KB
SI00499O, Instruction manual LTC50, LTC51PDF1138 KB
SI00500O, Instruction maunal LTC50, LTC51PDF1463 KB
SI00502O, Instruction manual LTC50, LTC51, LTC57PDF1279 KB
SI00503O, Instruction manual LTC50, LTC51, LTC57PDF1228 KB
SI00516O, Instruction manual LTC50, LTC51, LTC57PDF1297 KB
SI00517O, Instruction manual LTC51PDF1185 KB
SI00518O, Instruction manual LTC50, LTC51, LTC57PDF1546 KB
SI00519O, Instruction manual LTC50, LTC51PDF1150 KB
SI00520O, Instruction manual LTC50, LTC51PDF1524 KB
SI00522O, Instruction manual LTC50, LTC51, LTC57PDF1178 KB
SI00523O, Instruction manual LTC50, LTC51, LTC57PDF1166 KB
SI01125O, Instruction manual LTC50, LTC51, LTC57PDF1258 KB
SI01126O, Instruction manual LTC50, LTC51, LTC57PDF1256 KB
SI01127O, Instruction manual LTC51PDF1149 KB
SI01128O, Instruction manual LTC51PDF1150 KB
SI01130O, Instruction manual LTC50, LTC51, LTC57PDF1384 KB
SI01131O, Instruction manual LTC50, LTC51, LTC57PDF1380 KB
SI01132O, Instruction manual LTC50, LTC51, LTC57PDF1252 KB
SI01133O, Instruction manual LTC50, LTC51PDF1381 KB
SI01134O, Instruction manual LTC50, LTC51PDF1540 KB
SI01135O, Instruction manual LTC50, LTC51PDF1370 KB
SI01136O, Instruction manual LTC50, LTC51, LTC57PDF1304 KB
SD00326O, Handbuch Funktionale Sicherheit LTC5XPDF3257 KB
SI00497O, Betriebsanleitung LTC51PDF1065 KB
SI00498O, Betriebsanleitung LTC50, LTC51, LTC57PDF1252 KB
SI00499O, Betriebsanleitung LTC50, LTC51PDF1144 KB
SI00500O, Betriebsanleitung LTC50, LTC51PDF1480 KB
SI00502O, Betriebsanleitung LTC50, LTC51, LTC57PDF1277 KB
SI00503O, Betriebsanleitung LTC50, LTC51, LTC57PDF1233 KB
SI00516O, Betriebsanleitung LTC50, LTC51, LTC57PDF1302 KB
SI00517O, Betriebsanleitung LTC51PDF1190 KB
SI00518O, Betriebsanleitung LTC50, LTC51, LTC57PDF1553 KB
SI00519O, Betriebsanleitung LTC50, LTC51PDF1155 KB
SI00520O, Betriebsanleitung LTC50, LTC51PDF1533 KB
SI00522O, Betriebsanleitung LTC50, LTC51, LTC57PDF1184 KB
SI00523O, Betriebsanleitung LTC50, LTC51, LTC57PDF1171 KB
SI01125O, Betriebsanleitung LTC50, LTC51, LTC57PDF1264 KB
SI01126O, Betriebsanleitung LTC50, LTC51, LTC57PDF1261 KB
SI01127O, Betriebsanleitung LTC51PDF1155 KB
SI01128O, Betriebsanleitung LTC51PDF1148 KB
SI01130O, Betriebsanleitung LTC50, LTC51, LTC57PDF1390 KB
SI01131O, Betriebsanleitung LTC50, LTC51, LTC57PDF1385 KB
SI01132O, Betriebsanleitung LTC50, LTC51, LTC57PDF1257 KB
SI01133O, Betriebsanleitung LTC50, LTC51PDF1387 KB
SI01134O, Betriebsanleitung LTC50, LTC51PDF1549 KB
SI01135O, Betriebsanleitung LTC50, LTC51PDF1381 KB
SI01136O, Betriebsanleitung LTC50, LTC51, LTC57PDF1309 KB

CAD+CAE: LTC51

CADFil typeFil størrelse
CAD 3-D / CAD 3-DSTP1943 KB
CAD 3-D additional / CAD 3-D additionalSTP1782 KB
CAD Portal / CAD PortalLINK---

Tilhørende produkter: LTC51

Accessories
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Download from Pepperl+Fuchs websitepa
Device DTM, For level devices, Frame application, like e. g. PACTware, must be installed separatelypa
Functional Safety Hub from Pepperl+Fuchs

Several hundred products with a SIL/PL assessment, free tools, and brochures in one place: the "Functional Safety Hub" is your starting point when you have to implement safety functions.