Optical reading head PGV100I-F200-B16-V15

PGV100I-F200-B16-V15
  • Mechanically rugged: no wearing parts, long operating life, maintenance-free
  • CANopen interface
  • Non-contact positioning on Data Matrix code tape
  • Noncontact positioning with Data Matrix TAGs
  • Reading of Data Matrix control codes
  • Infrared light

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Uddrag af datablad: Tekniske data for   PGV100I-F200-B16-V15

Produkt beskrivelse
Read head for incident light positioning system
General specifications
Passage speed≤ 8 m/s
Measuring rangemax. 10000 m
Light typeIntegrated LED lightning , infrared
Scan rate40 s-1
Latency50 ms
Read distance100 mm
Depth of focus± 30 mm
Reading field120 mm x 80 mm
Ambient light limit100000 Lux
Accuracy± 0.2 mm
Nominal ratings
Camera
TypeCMOS , Global shutter
Processor
Clock pulse frequency600 MHz
Speed of computation4800 MIPS
Digital resolution32 Bit
Functional safety related parameters
MTTFd83 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
LED indication7 LEDs (communication, alignment aid, status information)
Electrical specifications
Operating voltage24 V DC ± 15% , PELV
No-load supply currentmax. 400 mA
Power consumption6 W
Interface
Interface typeCANopen , galvanically isolated
Data output codebinary code
Transfer ratemax. 1 MBit/s
Interface 2
Interface typeUSB Service
Input
Input type1 funtion input
0-level: -UBor unwired
1-level: +8 V ... +UB , programmable
Input impedance≥ 27 kΩ
Output
Output type1 to 3 switch outputs ,     programmable , short-circuit protected
Switching voltageOperating voltage
Switching current150 mA each output
Standard conformity
Emitted interferenceEN 61000-6-4:2007+A1:2011    
Noise immunityEN 61000-6-2:2005    
Shock resistanceEN 60068-2-27:2009
Vibration resistanceEN 60068-2-6:2008
Approvals and certificates
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Operating temperature0 ... 60 °C (32 ... 140 °F) ,   -20 ... 60 °C (-4 ... 140 °F) (noncondensing; prevent icing on the lens!)
Relative humidity90 % , noncondensing
Mechanical specifications
Connection type8-pin, M12x1 connector, standard (supply+IO)
5-pin, M12x1 socket, A-coded (bus out/termination)
5-pin, M12x1 connector, A-coded (bus in)
Degree of protectionIP67
Material
HousingPC/ABS
Massapprox. 200 g
Dimensions
Height70 mm
Width70 mm
Depth50 mm
Factory settings
X resolution (protocol)0.1 mm
Y resolution (protocol)0.1 mm
Speed resolution (protocol)0.1 m/s
Angle resolution0.1 °
Baud rate500 kBit/s
ExtrapolationOn
Read head address3

Classifications

SystemClasscode
ECLASS 13.027270918
ECLASS 12.027310101
ECLASS 11.027310101
ECLASS 10.0.127310101
ECLASS 9.027310101
ECLASS 8.027310101
ECLASS 5.127310101
ETIM 9.0EC004672
ETIM 8.0EC001852
ETIM 7.0EC001852
ETIM 6.0EC001852
ETIM 5.0EC001852
UNSPSC 12.143211711

Details: PGV100I-F200-B16-V15

Datasheet: PGV100I-F200-B16-V15

DatasheetFil typeFil størrelse
Datasheet PGV100I-F200-B16-V15PDF2077 KB
Fiche de données PGV100I-F200-B16-V15PDF2083 KB
Datenblatt PGV100I-F200-B16-V15PDF2078 KB
Hoja de datos PGV100I-F200-B16-V15PDF2087 KB

Documents: PGV100I-F200-B16-V15

ManualsFil typeFil størrelse
Manual Code Cards to configure the fieldbus addressPDF5321 KB
Manual PGV*-F200*-B16-V15PDF4858 KB
Handbuch Codekarten zur Konfiguration der FeldbusadressePDF5326 KB
Handbuch PGV*-F200*-B16-V15PDF3946 KB

CAD+CAE: PGV100I-F200-B16-V15

CADFil typeFil størrelse
CAD 3-D / CAD 3-DSTP4087 KB
CAD Portal / CAD PortalLINK---
EPLAN
CAE EPLAN Data Portal / CAE EPLAN Data PortalLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZEDZ315 KB

Approvals+Certificates: PGV100I-F200-B16-V15

Declaration of ConformityFil typeFil størrelse
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF43 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)PDF141 KB

Software: PGV100I-F200-B16-V15

Device DriverFil typeFil størrelse
EDS file PGV...I-F200x-B16-V15 / EDS-Datei PGV...I-F200x-B16-V15ZIP3 KB
Software Tools
Software Vision Configurator / Software Vision ConfiguratorZIP31588 KB

Tilhørende produkter: PGV100I-F200-B16-V15

Matching System Components

Data Matrix tag for PGV system, High chemical resistance, Low weight, Self-adhesive mounting, High temperature resistancefa
Data Matrix code tape, High chemical resistance, Low weight, Self-adhesive mounting, High temperature resistance, High mechanical stabilityfa
Control code tape für PGV System, High chemical resistance, Low weight, Self-adhesive mounting, High temperature resistance, High mechanical stabilityfa
Protective laminate for PGV code tape, High chemical resistance, Low weight, Self-adhesive mounting, High temperature resistance, High mechanical stabilityfa
Protective laminate for PGV code tape, High chemical resistance, Low weight, Self-adhesive mounting, High temperature resistance, High mechanical stabilityfa
Accessories

Female cordset single-ended M12 straight A-coded, 8-pin, PUR cable grey, shieldedfa
Grounding clip for PCV system, Stainless steel version, Low weight, M12 plug connection, High mechanical stabilityfa
Marker head for 25 mm code tape, For 25 mm code tapes, Can be used for PCV80..., PCV100..., and PCV130... readers, Includes 2 x edding® 3000 permanent markersfa
Mounting bracket for PCV* read headfa
Female cordset single-ended M12 straight A-coded, 8-pin, PUR cable grey, shieldedfa
Operating software for camera-based sensorsfa
USB cable unit with power supply, Power supply for 95 - 230 V AC, For SSI interface, For PROFIBUS DP, For CANopen, For PROFINET, For EtherNet/IPfa
Protective laminate for PGV code tape, High chemical resistance, Low weight, Self-adhesive mounting, High temperature resistance, High mechanical stability, Removable without residue, Easily interchangeablefa
Blind plug for M12 socketsfa
Functional Safety Hub from Pepperl+Fuchs

Several hundred products with a SIL/PL assessment, free tools, and brochures in one place: the "Functional Safety Hub" is your starting point when you have to implement safety functions.

Absolute positioning systems safePXV and safePGV

For the first time, the new absolute positioning systems safePXV and safePGV realize safety level SIL 3/PL e with a single sensor …