Support Industrielle sensorer
Support Explosion Protection

Inductive sensor NCB2-12GM35-N0-5M

NCB2-12GM35-N0-5M
  • 2 mm flush


NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below:

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Uddrag af datablad: Tekniske data for   NCB2-12GM35-N0-5M

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance2 mm
Installationflush
Assured operating distance0 ... 1.62 mm
Actual operating distance1.8 ... 2.2 mm typ.
Reduction factor rAl 0.23
Reduction factor rCu 0.21
Reduction factor r304 0.7
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Switching frequency0 ... 1000 Hz
Hysteresis1 ... 10 typ. 3 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected≤ 1 mA
Switching state indicatorall direction LED, yellow
Functional safety related parameters
MTTFd2099 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level GaIECEx PTB 11.0037X
Equipment protection level GbIECEx PTB 11.0037X
Equipment protection level DaIECEx PTB 11.0037X
Equipment protection level Dc (tc)IECEx TUR 21.0018X
Equipment protection level MbIECEx PTB 11.0037X
ATEX approval
Equipment protection level GaPTB 00 ATEX 2048 X
Equipment protection level GbPTB 00 ATEX 2048 X
Equipment protection level DaPTB 00 ATEX 2048 X
Equipment protection level Dc (tc)TÜV 20 ATEX 8524 X
UL approval
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0452
CCC approval
Hazardous Location2020322315002255
NEPSI approval
NEPSI certificateGYJ16.1393X
CML approvalon request
ANZEx18.3018X
KCC approval
Hazardous Location09-AV4BO-0226
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typecable
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP66 / IP67
Cable
Cable diameter4.6 mm ± 0.2 mm
Bending radius> 12 x cable diameter
MaterialPVC
Core cross section0.34 mm2
Length5 m
Dimensions
Length35 mm
Diameter12 mm
General information
Scope of delivery2 self locking nuts in scope of delivery
Use in the hazardous areasee instruction manuals

Classifications

SystemClasscode
ECLASS 13.027274001
ECLASS 12.027274001
ECLASS 11.027270101
ECLASS 10.0.127270101
ECLASS 9.027270101
ECLASS 8.027270101
ECLASS 5.127270101
ETIM 9.0EC002714
ETIM 8.0EC002714
ETIM 7.0EC002714
ETIM 6.0EC002714
ETIM 5.0EC002714
UNSPSC 12.139121550

Details: NCB2-12GM35-N0-5M

Documents: NCB2-12GM35-N0-5M

Instruction manualsFil typeFil størrelse
ИнструкцииPDF200 KB
Návod k poużitíPDF192 KB
Instruktions manualPDF190 KB
Instruction manualPDF192 KB
KasutusjuhendPDF185 KB
KäyttöohjePDF184 KB
Manuel d'instructionsPDF196 KB
BetriebsanleitungPDF191 KB
Οδηγίες χρήσηςPDF203 KB
HandleidingPDF191 KB
Instruction manual / BetriebsanleitungPDF189 KB
Használati útmutatóPDF194 KB
Manuale di istruzioniPDF193 KB
Lietošanas pamācībaPDF191 KB
Instrukciju vadovasPDF192 KB
Instrukcja obsługiPDF253 KB
Manual de instruçõesPDF195 KB
Manual de utilizarePDF195 KB
Návod na poużitiePDF192 KB
Navodila za uporaboPDF189 KB
Manual de instruccionesPDF195 KB
ManualPDF189 KB
Technical information
Mounting Instruction locking nut / Montageanleitung, Muttern mit SperrverzahnungPDF1117 KB
Installation conditionsPDF1054 KB
EinbaubedingungenPDF1060 KB

CAD+CAE: NCB2-12GM35-N0-5M

CADFil typeFil størrelse
CAD 3-D / CAD 3-DSTP51 KB
CAD Portal / CAD PortalLINK---
EPLAN
CAE EPLAN Data Portal / CAE EPLAN Data PortalLINK---
EPLAN macro EDZ / EPLAN Makro EDZEDZ64 KB

Approvals+Certificates: NCB2-12GM35-N0-5M

CertificatesFil typeFil størrelse
Australia AU Test Safe Group IPDF4026 KB
Canada USA UL Hazardous LocationPDF410 KB
Canada USA UL Ordinary LocationPDF1806 KB
China SITIIAS CCC Ex CertificatePDF3704 KB
EU PTB ATEX ia 2G, 1G, 1D s. certificatePDF12880 KB
Europe TUV Rheinland ATEX tc 3DPDF862 KB
Japan CML Ex iaPDF307 KB
KR KOSHA Ex iaPDF304 KB
United Kingdom CML UKEX Category I M2 UKEX Category II 2 G UKEX Category II 1 D UKEX Category II 1 GPDF541 KB
Worldwide PTB IECEx iaLINK---
Worldwide TUV Rheinland IECEx tcLINK---
Control Drawings
Control drawing UL / Control drawing ULPDF286 KB
Declaration of Conformity
EU Declaration of Conformity (P+F)PDF1411 KB
EU Declaration of Conformity (P+F)PDF1408 KB
EU Declaration of Conformity (P+F)PDF1406 KB
EU Declaration of Conformity (P+F)PDF1407 KB
UK Declaration of Conformity (P+F)PDF1381 KB
EU Declaration of Conformity (P+F)PDF1405 KB
EU Declaration of Conformity (P+F)PDF1404 KB
EU Declaration of Conformity (P+F)PDF1405 KB
EU-Konformitäterklärung (P+F)PDF1407 KB
EU Declaration of Conformity (P+F)PDF1412 KB
EU Declaration of Conformity (P+F)PDF1405 KB
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF1406 KB
EU Declaration of Conformity (P+F)PDF1409 KB
EU Declaration of Conformity (P+F)PDF1405 KB
EU Declaration of Conformity (P+F)PDF1406 KB
EU Declaration of Conformity (P+F)PDF1407 KB
EU Declaration of Conformity (P+F)PDF1408 KB
EU Declaration of Conformity (P+F)PDF1406 KB
EU Declaration of Conformity (P+F)PDF1407 KB
EU Declaration of Conformity (P+F)PDF1408 KB
EU Declaration of Conformity (P+F)PDF1406 KB
EU Declaration of Conformity (P+F)PDF1406 KB
EU Declaration of Conformity (P+F)PDF1405 KB
EU Declaration of Conformity (P+F)PDF1407 KB

Tilhørende produkter: NCB2-12GM35-N0-5M

Accessories

Mounting flange, 12 mmfa

Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here! 

 

 

Knowledge Base for Inductive Sensors

The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.

VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.